Accueil»Catalogue»I.V. Accessories»Extension tube (multi-lumen)»Triple lumen extension tube with Bionector
Octopus 3 with Bionector
Octopus 3 with Bionector is a polyurethane, transparent, supple multi-lumen extension tube for IV catheters (peripheral or central venous).
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
It allows to connect to the catheter several independant IV lines.
Code 841.364 is a triple lumen extension tube with 3 Bionector and 3 clamps (green, orange and white).
Length of tubes: 10 cm / 10 cm / 10 cm
Code 842.312 is a triple lumen extension tube with 3 non-return valves, 3 Bionector and 3 clamps (white, green, orange).
Length of tubes: 6 cm / 6 cm / 6 cm
Code 842.311 is a triple lumen extension tube with 2 non-return valves, 3 Bionector and 3 clamps (white, green, orange). The end without non-return valve allows the blood sampling.
Length of tubes: 6 cm / 6 cm / 6 cm
Used for central venous catheter care, Octopus 3 has the following advantages:
Non-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.
Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and hydrogen peroxide.
For more information about Bionector, please refer to the technical datasheet code 896.
Octopus with Bionector are also available with 1 lumen (code 5222.014), 2 lumen (codes 841.232/24/264/266E - 842.209), 4 lumen (code 842.414) and 5 lumen (code 842.514).
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
It allows to connect to the catheter several independant IV lines.
Code 841.364 is a triple lumen extension tube with 3 Bionector and 3 clamps (green, orange and white).
Length of tubes: 10 cm / 10 cm / 10 cm
Code 842.312 is a triple lumen extension tube with 3 non-return valves, 3 Bionector and 3 clamps (white, green, orange).
Length of tubes: 6 cm / 6 cm / 6 cm
Code 842.311 is a triple lumen extension tube with 2 non-return valves, 3 Bionector and 3 clamps (white, green, orange). The end without non-return valve allows the blood sampling.
Length of tubes: 6 cm / 6 cm / 6 cm
Used for central venous catheter care, Octopus 3 has the following advantages:
- Provides a closed and disinfectable system with needle-free access
- Eliminates the need to use a 3-way tap to run 2 or more simultaneous compatible solutions
- Eliminates the risk of blood spillage
- Eliminates the risk of air embolism
- PUR material (no PVC, no DEHP - no release of softeners)
Non-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.
Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and hydrogen peroxide.
For more information about Bionector, please refer to the technical datasheet code 896.
Octopus with Bionector are also available with 1 lumen (code 5222.014), 2 lumen (codes 841.232/24/264/266E - 842.209), 4 lumen (code 842.414) and 5 lumen (code 842.514).
Code |
Extension tube
Int. Ø mm |
Extension tube
Ext. Ø mm |
Extension tube
Length cm |
Extension tube
Priming volume ( with non-return valve) ml |
Extension tube
Priming volume (without non-return valve) ml |
Extension tube
Prim. vol. ml |
Extension tube
Total priming volume ml |
Extension tube
Flow rate (lumen with non return valve) ml/min |
Extension tube
Flow rate (lumen without non return valve) ml/min |
Extension tube
Flow rate ml/min |
---|---|---|---|---|---|---|---|---|---|---|
841.364 | 1.50 (x3) | 2.50 (x3) | 10 (x3) | - | - | 0.34 (x3) | 0.81 | - | - | 75 |
842.311 | 1.50 (x3) | 2.50 (x3) | 6 (x3) | 0.36 (x2) | 0.33 | - | 0.84 | 73 | 78 | - |
842.312 | 1.50 (x3) | 2.50 (x3) | 6 (x3) | 0.44 (x3) | - | - | 1.1 | - | - | - |
Extension tube | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Code | Int. Ø mm |
Ext. Ø mm |
Length cm |
Priming volume ( with non-return valve) ml |
Priming volume (without non-return valve) ml |
Prim. vol. ml |
Total priming volume ml |
Flow rate (lumen with non return valve) ml/min |
Flow rate (lumen without non return valve) ml/min |
Flow rate ml/min |
|
841.364 | 1.50 (x3) | 2.50 (x3) | 10 (x3) | - | - | 0.34 (x3) | 0.81 | - | - | 75 | |
842.311 | 1.50 (x3) | 2.50 (x3) | 6 (x3) | 0.36 (x2) | 0.33 | - | 0.84 | 73 | 78 | - | |
842.312 | 1.50 (x3) | 2.50 (x3) | 6 (x3) | 0.44 (x3) | - | - | 1.1 | - | - | - |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No
- Non-pyrogenic: Yes
- 1.79 Mo Bionector Product Range