Techniplex

Code produit: 5195.10

Techniplex is a set that allows nerve localization using a neurostimulation needle and then the introduction of the catheter through the needle.

This set is intended for continuous plexus and peripheral nerve blocks.

Introduction of the peri-nervous catheter through a Locoplex type needle with a 17° bevel, 30°short bevel or Tuohy bevel needle.

 

The Techniplex set includes:

 

  •  a Locoplex type needle with centimetric marking and insulating coating, only the bevel is conductive. This needle includes an electric cord ending in a female plug and a 50cm long transparent extension line (dead volume: 1ml). It is available either with a 30° bevel (codes 5195.xx3 and 5195.xx31), or with a Tuohy bevel (code 5195.xx6), or with a 17° bevel (code 5195.xx).
  •  a transparent PEBA (polyether blockamide) catheter tube with X.R.O line, with an Easy-lock connector. This catheter has a diameter of 0.45 x 0.85 mm and a length of 50cm. 

 

 

Catheters codes 5195.xx31 and 5195.xx6 are delivered WITH Teflon-coated stainless steel STYLET. They have a closed end with 3 side ports and a flexible distal tip.

 

Catheters codes 5195.xx and 5195.xx3 are delivered WITHOUT STYLET. They have an open distal end (without side ports). 

 

Marking: black mark on the tip to check that the entire catheter has been removed. Centimetric graduations from 1 to 20 cm, with a wider mark indicating the crossing of the bevel of the needle. It is presented in a Wishbone-type catheter pusher and protected by a plastic sheath.

 

  •  an additional 50cm extension line that can be connected to the peri-nervous catheter.
  •  a 10ml plastic Luer-lock syringe,
  •  a 0.2 µm flat anti-bacterial filter,
  •  a transparent adhesive dressing (polyurethane) Dermafilm 10 x 15 cm code 38.15.10,
  •  1 green label " Peripheral nerve block ".

 




  Code Catheter Int. Ø
mm
Catheter Ext. Ø
mm
Catheter Length
cm
Puncture needle Length
mm
Puncture needle G
G
Needle Bevel
Degree
5195.10 0.45 0.85 50 100 18 17
5195.103 0.45 0.85 50 100 18 30
5195.1031 0.45 0.85 50 100 18 30
5195.106 0.45 0.85 50 100 17 Tuohy
5195.12 0.45 0.85 50 120 18 17
5195.123 0.45 0.85 50 120 18 30
5195.1531 0.45 0.85 50 150 18 30
5195.156 0.45 0.85 50 150 17 Tuohy
5195.35 0.45 0.85 50 35 18 17
5195.353 0.45 0.85 50 35 18 30
5195.50 0.45 0.85 50 50 18 17
5195.503 0.45 0.85 50 50 18 30
5195.5031 0.45 0.85 50 50 18 30
5195.506 0.45 0.85 50 50 17 Tuohy
  Catheter Puncture needle Needle
Code Int. Ø
mm
Ext. Ø
mm
Length
cm
Length
mm
G
G
Bevel
Degree
5195.10 0.45 0.85 50 100 18 17
5195.103 0.45 0.85 50 100 18 30
5195.1031 0.45 0.85 50 100 18 30
5195.106 0.45 0.85 50 100 17 Tuohy
5195.12 0.45 0.85 50 120 18 17
5195.123 0.45 0.85 50 120 18 30
5195.1531 0.45 0.85 50 150 18 30
5195.156 0.45 0.85 50 150 17 Tuohy
5195.35 0.45 0.85 50 35 18 17
5195.353 0.45 0.85 50 35 18 30
5195.50 0.45 0.85 50 50 18 17
5195.503 0.45 0.85 50 50 18 30
5195.5031 0.45 0.85 50 50 18 30
5195.506 0.45 0.85 50 50 17 Tuohy
  • Contains Latex: No
  • Contains DEHP: No
  • Contains biogical or animal-based product: No
  • Non-pyrogenic: Yes