Home»Catalogue»I.V. Accessories»Extension tube (multi-lumen)»Triple lumen extension tube with Bionector

Octopus 3 with Bionector

Product code: 842.311

Octopus 3 with Bionector is a polyurethane, transparent, supple multi-lumen extension tube for IV catheters (peripheral or central venous).
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
It allows to connect to the catheter several independant IV lines.
Code 841.34 is a triple lumen extension tube with 3 Bionector and 3 clamps (white). 
Length of tubes: 8 cm / 10 cm / 6 cm
Code 841.364 is a triple lumen extension tube with 3 Bionector and 3 clamps (green, orange and white). 
Length of tubes: 10 cm / 10 cm / 10 cm
Code 842.312 is a triple lumen extension tube with 3 anti-return valves, 3 Bionector and 3 clamps (white, green, orange).
Length of tubes: 6 cm / 6 cm / 6 cm
Code 842.311 is a triple lumen extension tube with 2 anti-return valves, 3 Bionector and 3 clamps (white, green, orange). The end without anti-retourn valve allows the sampling blood.
Length of tubes: 6 cm / 6 cm / 6 cm
Code 842.306 is a triple lumen extension tube with 2 anti-return valves, 3 Bionector ans 3 Robert clamps (blue, white, black).The end without anti-retourn valve allows the sampling blood.
Length of tubes: 6 cm / 6 cm / 6 cm
Used for central venous catheter care, Octopus 3 has the following advantages:
- Provides closed, neelde-free access during syringe bolus dose administration and I.V. tubing change
- Eliminates the need to use a 3-way tap to run 2 or more simultaneous compatible solutions
- Eliminates the risk of blood spillage
- Eliminates the risk of air embolism
- PUR material (no PVC, no DEHP - no release of softeners)
Anti-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.
Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and oxygenated water.
For more information about Bionector, please refer to technical file code 896.
Octopus with Bionector are also available with 1 lumen (code 5222.014), 2 lumen (codes 841.232/24/25/26/264/266E - 842.209), 4 lumen (code 842.414) and 5 lumen (code 842.514).


  Code Extension tube Int. Ø
mm
Extension tube Ext. Ø
mm
Extension tube Length
cm
Extension tube Priming volume ( with non-return valve)
ml
Extension tube Priming volume (without non-return valve)
ml
Extension tube Prim. vol.
ml
Extension tube Total priming volume
ml
Extension tube Flow rate (lumen with non return valve)
ml/min
Extension tube Flow rate (lumen without non return valve)
ml/min
Extension tube Flow rate
ml/min
841.364 1.50 (x3) 2.50 (x3) 10 (x3) - - 0.34 (x3) 0.81 - - 75
841.365 1.50 (x3) 2.50 (x3) 10 (x3) - - 0.34 (x3) - - - -
842.311 1.50 (x3) 2.50 (x3) 6 (x3) 0.36 (x2) 0.33 - 0.84 73 78 -
842.312 1.50 (x3) 2.50 (x3) 6 (x3) 0.44 (x3) - - 1.1 - - -
  Extension tube
Code Int. Ø
mm
Ext. Ø
mm
Length
cm
Priming volume ( with non-return valve)
ml
Priming volume (without non-return valve)
ml
Prim. vol.
ml
Total priming volume
ml
Flow rate (lumen with non return valve)
ml/min
Flow rate (lumen without non return valve)
ml/min
Flow rate
ml/min
841.364 1.50 (x3) 2.50 (x3) 10 (x3) - - 0.34 (x3) 0.81 - - 75
841.365 1.50 (x3) 2.50 (x3) 10 (x3) - - 0.34 (x3) - - - -
842.311 1.50 (x3) 2.50 (x3) 6 (x3) 0.36 (x2) 0.33 - 0.84 73 78 -
842.312 1.50 (x3) 2.50 (x3) 6 (x3) 0.44 (x3) - - 1.1 - - -
  • Contains Latex: No
  • Contains DEHP: No
  • Contains products of animal or biological origin: No
  • Pyrogen-free: Yes