Mini-sitimplant

Product code: 2201.61

Low-profile titanium implantable port, encased in silicone, specially designed for smaller patients (adults and children).
  • I.V. catheter in fully radiopaque silicone, 60cm long and anti -kinking sleeve. Markings every centimetre along the length of the catheter,
  • Integral (codes 2201.62/66) or attachable (codes 2201.61/63/65) catheter according to physician's preference,
  • Compatible with magnetic resonance imaging.

2 kits are available:

1 simple kit without introducer (2201.61, 2201.62, 2201.65, 2201.66):
  • 1 Mini-Sitimplant implantable port with silicone catheter
  • 1 Inject-site, needle 22G, 25mm with Huber bevel for injection
  • 1 vein pick catheter guide
  • 1 Hubsite, needle with Huber bevel for infusion
  • 1 female Luer adapter to prime attachable catheters


1 kit with introducer (code 2201.63):
  • 1 implantable port type Mini-Sitimplant with silicone catheter
  • 1 Inject-site, needle 22G, 25mm with Huber bevel for injection
  • 1 vein pick catheter guide
  • 1 Hubsite, needle with Huber bevel for perfusion
  • 1 female Luer adaptor to prime attachable catheters
  • 1 peelable Desilet (needle + BLS valve, J guidewire Nitinol)
  • 1 syringe 10ml


  Code Catheter Length
cm
Catheter Int. Ø
mm
Catheter Ext. Ø
mm
Catheter Ø
Fr
Catheter Type Implantable port Weight
g
Implantable port Prim. vol.
ml
Implantable port Height
mm
Implantable port Base Ø
mm
Implantable port Puncture area
cm²
Implantable port Nber of fixation holes Implantable port Septum Ø
mm
Implantable port Ø
mm
Introducer Type
2201.311 60 1.1 2.2 6.6 Attachable 11 0.51 13.5 32 1.3 5 - - -
2201.315 60 1.1 2.8 8.4 Attachable 11 0.51 13.5 32 1.3 5 - - -
2201.32 60 1.1 2.2 6.6 Integral 11 0.51 13.5 32 1.3 5 - - -
2201.33 60 1.1 2.2 6.6 Attachable 11 0.51 13.5 32 1.3 5 - - 1146
2201.335 60 1.1 2.80 8.5 Attachable 11 0.51 13.5 32 1.3 5 - - 1146
2201.37 60 1.1 2.2 6.6 Attachable 11 0.51 13.5 32 1.3 5 - - 1137
2201.39 60 1.1 2.0 6 Attachable 11 0.51 13.5 32 1.3 5 - - 122.27
2201.411 60 1.6 3.2 9.6 Attachable 11 0.51 13.5 32 1.3 5 - - -
2201.42 60 1.6 3.2 9.6 Integral 11 0.51 13.5 32 1.3 5 - - -
2201.51 90 0.5 1.0 19 - 4.3 0.29 10.5 - 0.63 - - 23 -
2201.61 60 1.1 2.2 6.6 Attachable 4.3 0.29 10.5 23 0.6 4 - - -
2201.62 60 1.1 2.2 6.6 Integral 4.3 0.29 10.5 23 0.6 4 - - -
2201.63 60 1.1 2.2 6.6 Attachable 4.3 0.29 10.5 23 0.6 4 - - -
2201.65 60 0.8 1.3 4 Attachable 4.3 0.29 10.5 23 0.6 4 - - -
2201.66 60 0.8 1.3 4 Integral 4.3 0.29 10.5 23 0.6 4 - - -
2211.61 80 1.1 2.2 6.6 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.67 80 1.1 2.2 6.6 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.68 80 1.1 2.2 6.6 Integral - 0.17 8 - 0.6 6 - 19 -
2211.71 80 0.8 1.3 4 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.77 80 0.8 1.3 4 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.78 80 0.8 1.3 4 Integral - 0.17 8 - 0.6 6 - 19 -
2211.91 80 1.0 1.7 5.1 Detachable - 0.17 8 - 0.6 6 - 19 -
2215.014 60 0.8 1.3 4 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.016 60 1.1 2.2 6.6 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.017 60 1.1 2.80 8.4 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.019 60 1.6 3.2 9.6 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.024 60 0.8 1.3 4 Integral 8 0.27 10 24 0.8 4 10 - -
2215.026 60 1.1 2.2 6.6 Integral 8 0.27 10 24 0.8 4 10 - -
2215.116 60 1.1 2.2 6.6 Detachable 8 0.27 10 24 0.8 4 10 - 1146.07
2215.117 60 1.1 2.8 8.4 Detachable 8 0.27 10 24 0.8 4 10 - 1146.09
2215.119 60 1.6 3.2 9.6 Detachable 8 0.27 10 24 0.8 4 10 - 1146.10
2215.125 60 1.0 1.7 5.1 Integral 8 0.27 10 24 0.8 4 10 - 1146.05
2215.126 60 1.1 2.2 6.6 Integral 8 0.27 10 24 0.8 4 10 - 1146.07
2215.129 60 1.6 3.2 9.6 Integral 8 0.27 10 24 0.8 4 10 - 1146.10
2215.216 60 1.1 2.0 6 Detachable 8 0.27 10 24 0.8 5 10 - 122.27
2216.016 60 1.1 2.2 6.6 detachable 10.5 0.35 11 28 1.3 4 13 - -
2216.017 60 1.1 2.8 8.4 detachable 11 0.35 11 28 1.3 4 13 - -
2216.019 60 1.6 3.2 9.6 detachable 10.5 0.35 11 28 1.3 4 13 - -
2216.026 60 1.1 2.2 6.6 Integral 10.5 0.35 11 28 1.3 4 13 - -
2216.029 60 1.6 3.2 9.6 Integral 10.5 0.35 11 28 1.3 4 13 - -
2216.116 60 1.1 2.2 6.6 detachable 11.7 0.35 11 28 1.3 4 13 - 1146.07
2216.117 60 1.1 2.8 8.4 detachable 11.7 0.35 11 28 1.3 4 13 - 1146.09
2216.119 60 1.6 3.2 9.6 detachable 11.7 0.35 11 28 1.3 4 13 - 1146.10
2216.126 60 1.1 2.2 6.6 Integral 11.7 0.35 11 28 1.3 4 13 - 1146.07
2216.129 60 1.6 3.2 9.6 Integral 11.7 0.35 11 28 1.3 4 13 - 1146.10
2216.216 60 1.1 2.0 6 detachable 10.5 0.35 11 28 1.3 5 13 - 122.27
  Catheter Implantable port Introducer
Code Length
cm
Int. Ø
mm
Ext. Ø
mm
Ø
Fr
Type Weight
g
Prim. vol.
ml
Height
mm
Base Ø
mm
Puncture area
cm²
Nber of fixation holes Septum Ø
mm
Ø
mm
Type
2201.311 60 1.1 2.2 6.6 Attachable 11 0.51 13.5 32 1.3 5 - - -
2201.315 60 1.1 2.8 8.4 Attachable 11 0.51 13.5 32 1.3 5 - - -
2201.32 60 1.1 2.2 6.6 Integral 11 0.51 13.5 32 1.3 5 - - -
2201.33 60 1.1 2.2 6.6 Attachable 11 0.51 13.5 32 1.3 5 - - 1146
2201.335 60 1.1 2.80 8.5 Attachable 11 0.51 13.5 32 1.3 5 - - 1146
2201.37 60 1.1 2.2 6.6 Attachable 11 0.51 13.5 32 1.3 5 - - 1137
2201.39 60 1.1 2.0 6 Attachable 11 0.51 13.5 32 1.3 5 - - 122.27
2201.411 60 1.6 3.2 9.6 Attachable 11 0.51 13.5 32 1.3 5 - - -
2201.42 60 1.6 3.2 9.6 Integral 11 0.51 13.5 32 1.3 5 - - -
2201.51 90 0.5 1.0 19 - 4.3 0.29 10.5 - 0.63 - - 23 -
2201.61 60 1.1 2.2 6.6 Attachable 4.3 0.29 10.5 23 0.6 4 - - -
2201.62 60 1.1 2.2 6.6 Integral 4.3 0.29 10.5 23 0.6 4 - - -
2201.63 60 1.1 2.2 6.6 Attachable 4.3 0.29 10.5 23 0.6 4 - - -
2201.65 60 0.8 1.3 4 Attachable 4.3 0.29 10.5 23 0.6 4 - - -
2201.66 60 0.8 1.3 4 Integral 4.3 0.29 10.5 23 0.6 4 - - -
2211.61 80 1.1 2.2 6.6 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.67 80 1.1 2.2 6.6 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.68 80 1.1 2.2 6.6 Integral - 0.17 8 - 0.6 6 - 19 -
2211.71 80 0.8 1.3 4 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.77 80 0.8 1.3 4 Detachable - 0.17 8 - 0.6 6 - 19 -
2211.78 80 0.8 1.3 4 Integral - 0.17 8 - 0.6 6 - 19 -
2211.91 80 1.0 1.7 5.1 Detachable - 0.17 8 - 0.6 6 - 19 -
2215.014 60 0.8 1.3 4 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.016 60 1.1 2.2 6.6 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.017 60 1.1 2.80 8.4 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.019 60 1.6 3.2 9.6 Detachable 8 0.27 10 24 0.8 4 10 - -
2215.024 60 0.8 1.3 4 Integral 8 0.27 10 24 0.8 4 10 - -
2215.026 60 1.1 2.2 6.6 Integral 8 0.27 10 24 0.8 4 10 - -
2215.116 60 1.1 2.2 6.6 Detachable 8 0.27 10 24 0.8 4 10 - 1146.07
2215.117 60 1.1 2.8 8.4 Detachable 8 0.27 10 24 0.8 4 10 - 1146.09
2215.119 60 1.6 3.2 9.6 Detachable 8 0.27 10 24 0.8 4 10 - 1146.10
2215.125 60 1.0 1.7 5.1 Integral 8 0.27 10 24 0.8 4 10 - 1146.05
2215.126 60 1.1 2.2 6.6 Integral 8 0.27 10 24 0.8 4 10 - 1146.07
2215.129 60 1.6 3.2 9.6 Integral 8 0.27 10 24 0.8 4 10 - 1146.10
2215.216 60 1.1 2.0 6 Detachable 8 0.27 10 24 0.8 5 10 - 122.27
2216.016 60 1.1 2.2 6.6 detachable 10.5 0.35 11 28 1.3 4 13 - -
2216.017 60 1.1 2.8 8.4 detachable 11 0.35 11 28 1.3 4 13 - -
2216.019 60 1.6 3.2 9.6 detachable 10.5 0.35 11 28 1.3 4 13 - -
2216.026 60 1.1 2.2 6.6 Integral 10.5 0.35 11 28 1.3 4 13 - -
2216.029 60 1.6 3.2 9.6 Integral 10.5 0.35 11 28 1.3 4 13 - -
2216.116 60 1.1 2.2 6.6 detachable 11.7 0.35 11 28 1.3 4 13 - 1146.07
2216.117 60 1.1 2.8 8.4 detachable 11.7 0.35 11 28 1.3 4 13 - 1146.09
2216.119 60 1.6 3.2 9.6 detachable 11.7 0.35 11 28 1.3 4 13 - 1146.10
2216.126 60 1.1 2.2 6.6 Integral 11.7 0.35 11 28 1.3 4 13 - 1146.07
2216.129 60 1.6 3.2 9.6 Integral 11.7 0.35 11 28 1.3 4 13 - 1146.10
2216.216 60 1.1 2.0 6 detachable 10.5 0.35 11 28 1.3 5 13 - 122.27
  • Contains Latex: No
  • Contains DEHP: No
  • Contains products of animal or biological origin: No
  • Pyrogen-free: Yes

IMPORTANT NOTICE

In this sensitive period due to the coronavirus (COVID-19), the health and safety of Vygon’s employees, as well as all of the stakeholders carrying out our activities, is a top priority for us.
Vygon’s goal is to ensure everyone’s protection, whilst maintaining the best levels of service and quick response to our customer’s needs.

As we are acutely aware of our role in the chain of care, we have taken steps to optimize order management.

Recurring scheduled orders will be delivered as usual: we have planned all necessary stock. Exceptional orders (urgent or consisting of very large quantities) are being analyzed in order to best distribute stock amongst all of our customers. As a result, some orders may be fragmented, for the sake of stock control and solidarity. We thank you for your continued support and understanding.

Whilst protecting all of our customers, we will continue to help those who are on the front line fighting this virus: doctors, nurses, all caregivers and, of course, your patients, as we have always done.