Maxflo Expert (guidewire of 50 cm)

Product code: 8394.15

Maxflo Expert is a radiopaque peripherally inserted central catheter designed for medium and long-term IV therapy which can also be used for CT-rated injections of contrast media. Pressure resistance: 325 psi (22.4 bar).Maxflo Expert is made of biostable polyurethane which allows a long-term use of the catheter (several months if necessary). It is supplied with a stylet to facilitate its insertion.
Other features of the product:
  • Length of catheter 55cm
  • Radiopaque
  • Antimicrobial (Antimicrobial agent: Agion technology based on silver ions) 
  • Centimetric graduations and numerical markings
  • 1, 2 or 3 lumen
  • 1 Stylet
  • 1 Introducer Micro-Seldinger type with safe micro puncture needle (21G)
Maxflo Expert can be used for parenteral nutrition, chemotherapy, antibiotherapy, pain treatment, administration of drugs etc... and is suitable for use with power injectors (CT scan).
Maxflo Expert is supplied in a rigid blister pack (double packaging) containing:
  • 1 antimicrobial catheter,  winged hub and integral extension tube (length 9cm) with Roberts clamp with a printed inlay with on one side “maximum flow rate” and on the other side “325 psi”
  • 1 stylet to make the catheter more rigid and thus facilitate its insertion
  • 1 "T" proximal connector. The lateral port of the T connector allows the injection of saline solution (with a syringe) to lubricate the stylet and facilitate its sliding on removal or to inject saline solution in case of venous spasm, to open the path
  • 1 echogenic puncture needle of small diameter 21G with safety features to avoid the risk of needle-stick injury
  • 1 Nitinol guidewire with stainless steel flexible tip and guide advancer, Ø 0.46mm, length 50cm
  • 1 peel-away Desilet length 7cm
  • 1 safety scalpel
  • 1 Bionector (2 Bionector for double lumen Maxflo, 3 Bionector for triple lumen Maxflo)
  • 1 syringe 10ml
  • 1 tape measure
  • 1 Grip-Lok stabilization device (available in sterile individual packaging under code 5804.10)

Other types of kits are available:
  • Maxflo with a 67cm guidewire: see technical file code 8394.405/406/414/415/425/426/436,
  • Maxflo with a 137cm guidewire, without stylet, for "over the wire insertion" see technical file: code 8394.505/506/514/515/525/526/536. 


  Code Catheter Lumen Catheter Ø
Fr
Catheter Ext. Ø
mm
Catheter Length
cm
Catheter Flow rate
ml/min
Catheter Prim. vol.
ml
Catheter Proximal end Catheter Max. flow rate
ml/s
Catheter Max. pressure
bar
Guidewire Length
cm
Guidewire Ø
mm
Distal lumen Flow rate
ml/min
Distal lumen Prim. vol.
ml
8394.105 1 5 1.75 55 46 1.0 Non tapered 7 22.4 50 0.46 - -
8394.14 1 4 1.35 55 19 0.8 Tapered 5 22.4 50 0.46 - -
8394.15 1 5 1.7 55 28 0.8 Non tapered 6 22.4 50 0.46 - -
8394.206 2 6 2.0 55 14 0.8 - 6 22.4 50 0.46 - -
8394.25 2 5 1.75 55 9 0.75 (x2) Tapered 5 22.4 50 0.46 - -
8394.26 2 6 2.0 55 - - - - - 500 0.46 14 (x2) 0.7 (x2)
8394.36 3 6 2.0 55 4 - 10 - 4 0.45 - 0.85 - 0.45 Tapered 5 22.4 50 0.46 - -
8394.405 1 5 1.75 55 46 1.0 Tapered 7 22.4 67 0.46 - -
8394.406 2 6 2.0 55 14 (x2) 0.8 (x2) Tapered 6 22.4 67 0.46 - -
8394.414 1 4 1.35 55 19 0.8 Tapered 5 22.4 67 0.46 - -
8394.415 1 5 1.70 55 28 0.8 Non tapered 6 22.4 67 0.46 - -
8394.425 2 5 1.75 55 9 (x2) 0.75 (x2) Tapered 5 22.4 67 0.46 - -
8394.426 2 6 2.0 55 14 (x2) 0.8 (x2) Non tapered 5 22.4 67 0.46 - -
8394.436 3 6 2.0 55 4 - 10 - 4 0.45 - 0.85 - 0.45 Tapered 5 22.4 67 0.46 - -
8394.505 1 5 1.75 55 46 1.0 Tapered 7 22.4 135 0.46 - -
8394.506 2 6 2.0 55 14 (x2) 0.8 (x2) - 6 22.4 135 0.46 - -
8394.514 1 4 1.35 55 19 0.8 Tapered 5 22.4 135 0.46 - -
8394.515 1 5 1.7 55 28 0.8 Non tapered 6 22.4 135 0.46 - -
8394.525 2 5 1.75 55 9 (x2) 0.75 (x2) Tapered 5 22.4 135 0.46 - -
8394.526 2 6 2.0 55 14 (x2) 0.8 (x2) Non tapered 5 22.4 135 0.46 - -
8394.536 3 6 2.0 55 4 - 10 - 4 0.45 - 0.85 - 0.45 Tapered 5 22.4 135 0.46 - -
  Catheter Guidewire Distal lumen
Code Lumen Ø
Fr
Ext. Ø
mm
Length
cm
Flow rate
ml/min
Prim. vol.
ml
Proximal end Max. flow rate
ml/s
Max. pressure
bar
Length
cm
Ø
mm
Flow rate
ml/min
Prim. vol.
ml
8394.105 1 5 1.75 55 46 1.0 Non tapered 7 22.4 50 0.46 - -
8394.14 1 4 1.35 55 19 0.8 Tapered 5 22.4 50 0.46 - -
8394.15 1 5 1.7 55 28 0.8 Non tapered 6 22.4 50 0.46 - -
8394.206 2 6 2.0 55 14 0.8 - 6 22.4 50 0.46 - -
8394.25 2 5 1.75 55 9 0.75 (x2) Tapered 5 22.4 50 0.46 - -
8394.26 2 6 2.0 55 - - - - - 500 0.46 14 (x2) 0.7 (x2)
8394.36 3 6 2.0 55 4 - 10 - 4 0.45 - 0.85 - 0.45 Tapered 5 22.4 50 0.46 - -
8394.405 1 5 1.75 55 46 1.0 Tapered 7 22.4 67 0.46 - -
8394.406 2 6 2.0 55 14 (x2) 0.8 (x2) Tapered 6 22.4 67 0.46 - -
8394.414 1 4 1.35 55 19 0.8 Tapered 5 22.4 67 0.46 - -
8394.415 1 5 1.70 55 28 0.8 Non tapered 6 22.4 67 0.46 - -
8394.425 2 5 1.75 55 9 (x2) 0.75 (x2) Tapered 5 22.4 67 0.46 - -
8394.426 2 6 2.0 55 14 (x2) 0.8 (x2) Non tapered 5 22.4 67 0.46 - -
8394.436 3 6 2.0 55 4 - 10 - 4 0.45 - 0.85 - 0.45 Tapered 5 22.4 67 0.46 - -
8394.505 1 5 1.75 55 46 1.0 Tapered 7 22.4 135 0.46 - -
8394.506 2 6 2.0 55 14 (x2) 0.8 (x2) - 6 22.4 135 0.46 - -
8394.514 1 4 1.35 55 19 0.8 Tapered 5 22.4 135 0.46 - -
8394.515 1 5 1.7 55 28 0.8 Non tapered 6 22.4 135 0.46 - -
8394.525 2 5 1.75 55 9 (x2) 0.75 (x2) Tapered 5 22.4 135 0.46 - -
8394.526 2 6 2.0 55 14 (x2) 0.8 (x2) Non tapered 5 22.4 135 0.46 - -
8394.536 3 6 2.0 55 4 - 10 - 4 0.45 - 0.85 - 0.45 Tapered 5 22.4 135 0.46 - -
  • Contains Latex: No
  • Contains DEHP: No
  • Contains products of animal or biological origin: No
  • Pyrogen-free: Yes

IMPORTANT NOTICE

In this sensitive period due to the coronavirus (COVID-19), the health and safety of Vygon’s employees, as well as all of the stakeholders carrying out our activities, is a top priority for us.
Vygon’s goal is to ensure everyone’s protection, whilst maintaining the best levels of service and quick response to our customer’s needs.

As we are acutely aware of our role in the chain of care, we have taken steps to optimize order management.

Recurring scheduled orders will be delivered as usual: we have planned all necessary stock. Exceptional orders (urgent or consisting of very large quantities) are being analyzed in order to best distribute stock amongst all of our customers. As a result, some orders may be fragmented, for the sake of stock control and solidarity. We thank you for your continued support and understanding.

Whilst protecting all of our customers, we will continue to help those who are on the front line fighting this virus: doctors, nurses, all caregivers and, of course, your patients, as we have always done.