Freedom 5

Code produit: 7301.05

Single-use mechanical device for patient-controlled analgesia.
Freedom 5 has been specially designed for pain management in the Accident and Emergency department or in the recovery room for the treatment of post-operative pain. This product is also indicated for pain treatment of patients suffering from sickle cell disease.
It can be easily set-up by healthcare personnel and is extremely simple for the patient to use: if he feels pain, all he has to do is press the lever. Freedom 5 allows the patient to self-administer a pre-set quantity of intravenous morphine equivalent to:
  • 0.5 ml for model 7301.05 / 7301.50 / 7301.501. The lock-out for bolus reconstitution is 5 minutes*.
NB: As the bolus reservoir is under negative pressure downloading is not possible.

The Freedom 5 kit - 7301.05 contains:
  • 1 PCA reservoir carrier with inspection window to check the amount of morphine remaining in the reservoir. A bolus chamber 0.5 ml is located at the bottom part of the reservoir carrier 
  • 1 calibrated reservoir (55 ml). This reservoir must be locked within the carrier making sure that the graduations of the reservoir are visible in the inspection window of the carrier 
  • 1 capping device with lever 
  • 1 attachment cord 
  • 1 polyethylene storage bag 
  • 1 female/female Luer-lock adaptor (code 892) for filling the reservoir with a syringe 
  • 1 female Luer-lock obturator (code 888) 
  • 1 single-lumen extension tube (length 125 cm) with antibacterial and air-eliminating filter, anti-siphon valve and Bionector**.

*Other models of Freedom 5 PCA with a bolus chamber of 1ml and duration for bolus reconstitution of 7 minutes are available. See technical file 7301.10 / 7301.12
**For Bionector: see technical file 896


  Code Extension tube lumen 2 Priming volume
ml
Extension tube lumen 2 Length
cm
Extension tube lumen 2 Internal diameter
mm
Extension tube lumen 2 External diameter
mm
Freedom 5 Bolus
ml
Freedom 5 Duration of bolus reconstitution
min.
Extension tube Prim. vol.
ml
Extension tube Length
cm
Extension tube Int. Ø
mm
Extension tube Ext. Ø
mm
7301.05 - - - - 0.5 5 2.7 125 1.5 2.5
7301.10 - - - - 1.0 7 2.7 125 1.5 2.5
7301.12 0.37 5 1.85 2.6 1.0 7 - - - -
7301.50 - - - - 0.5 5 2.7 125 1.50 2.50
7301.501 0.38 5 1.85 2.6 0.5 5 1.2 90 1.0 2.15
  Extension tube lumen 2 Freedom 5 Extension tube
Code Priming volume
ml
Length
cm
Internal diameter
mm
External diameter
mm
Bolus
ml
Duration of bolus reconstitution
min.
Prim. vol.
ml
Length
cm
Int. Ø
mm
Ext. Ø
mm
7301.05 - - - - 0.5 5 2.7 125 1.5 2.5
7301.10 - - - - 1.0 7 2.7 125 1.5 2.5
7301.12 0.37 5 1.85 2.6 1.0 7 - - - -
7301.50 - - - - 0.5 5 2.7 125 1.50 2.50
7301.501 0.38 5 1.85 2.6 0.5 5 1.2 90 1.0 2.15
  • Contains Latex: No
  • Contains DEHP: No
  • Contains biogical or animal-based product: No
  • Non-pyrogenic: Yes