Accueil»Catalogue»I.V. Accessories»Extension tube (multi-lumen)»Double lumen extension tube with Bionector

Protect-a-set / Octopus 2

Code produit: 841.232

Protect-a-set (code 836.02) and Octopus 2 (other codes) are polyurethane, transparent, supple with low dead space double-lumen extension tubes for IV catheters (peripheral or central venous) fitted with one or 2 Bionector.
To identify the different infusion lines, each line has a hub or a clamp of a different colour.
They allow to connect to the catheter several independant IV lines.

Code 836.02 is a double lumen extension tube with 1 non-return valve, 1 hub with Bionector and 1 clamp (white).
Length of tubes: 6 cm / 10 cm.
Code 841.232 is a double lumen extension tube with 2 non-return valves, 2 Bionector and 2 clamps (green). 
Length of tubes: 3 cm / 3 cm.
Code 841.264 is a double lumen extension tube with 2 Bionector and 2 clamps (green and orange). 
Length of tubes: 10 cm / 10 cm.
Code 842.209 is a double lumen extension tube with 1 non-return valve, 2 Bionector and 2 clamps (green and orange). The end without non-return valve allows the sampling blood.
Length of tubes: 6 cm / 6 cm

Used for peripheral cannula care, Octopus 2 has the following advantages:
  • Eliminates the risk of access-associated needle-stick injury
  • Reduces the risk of cannula movement in the vein causing mechanical vein irritation
  • Negates the need to use the cannula injection port (non disinfectable), Bionector is disinfectable
  • Eliminates the need to use a 3-way tap to run simultaneous compatible solutions
  • Provides closed system (avoiding blood reflux) when accessing the catheter
  • PUR material (no PVC, DEHP-free - no release of softeners)

Non-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.

Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and hydrogen peroxide.
For more information about Bionector, please refer to technical file code 896.

Octopus with Bionector are also available with 1 lumen (code 5222.014), 3 lumen (codes 841.364-842.311/312), 4 lumen (code 842.414) and 5 lumen (code 842.514). 


  Code Extension tube Total priming volume
ml
Lumen 1 Flowrate
ml/min
Lumen 1 Length
cm
Lumen 1 Int. Ø
mm
Lumen 1 External diameter
mm
Lumen 1 Priming volume
ml
Lumen 2 Flowrate
ml/min
Lumen 2 Length
cm
Lumen 2 Int. Ø
mm
Lumen 2 External diameter
mm
Lumen 2 Priming volume
ml
841.232 0.50 78 3 1.50 2.50 0.30 78 3 1.50 2.50 0.30
841.264 0.57 82 10 1.50 2.50 0.34 82 10 1.50 2.50 0.34
842.209 0.58 73 6 1.50 2.50 0.36 78 6 1.50 2.50 0.33
  Extension tube Lumen 1 Lumen 2
Code Total priming volume
ml
Flowrate
ml/min
Length
cm
Int. Ø
mm
External diameter
mm
Priming volume
ml
Flowrate
ml/min
Length
cm
Int. Ø
mm
External diameter
mm
Priming volume
ml
841.232 0.50 78 3 1.50 2.50 0.30 78 3 1.50 2.50 0.30
841.264 0.57 82 10 1.50 2.50 0.34 82 10 1.50 2.50 0.34
842.209 0.58 73 6 1.50 2.50 0.36 78 6 1.50 2.50 0.33
  • Contains Latex: No
  • Contains DEHP: No
  • Contains biogical or animal-based product: No
  • Non-pyrogenic: Yes